Technical blog

TEST BENCH FILTRATION

The problem

A typical error when oleodinamic components test bench filtration is designed, is to use oleodinamic filters instead process filters. Oleodinamic filter elements obtain immediately an optimum cleanliness level. They are designed to block a small amount of particles, since it’s given as a fact that a correct designed system produce a limited quantity of particles. 



The cause

Process filter elements instead, are designed to catch big amounts of particles during the production process and their cost usually is not so high as an hydraulic element. 

The solution

An accurate filter/filter elements choice, permits to obtain an high cleanliness fluid level at sensible lower cost than a traditional system. In these pictures, is possible to see at a test bench filtration system realized by our company with process filters.
 

© 2018 La Ricambi Udinese | Privacy Policy | Cookie policy | Legal and Conditions of Business | Admin